5-18
output. You will be prompted to enter stamp commands only if the Input Type is S.
The Stamp Commands are:
M - Month (01-12)
D - Day of Month (01-31)
Y - Year (00-99)
H - Hour (00-23)
I - Minute (00-59)
S - Second (00-59)
W - Day of Week (0-6)
NOTE: The output during transmission will be two numeric digits for all the commands except
W, Day of Week. The Day of Week is output as one numeric digit, 0 being Sunday and 6
being Saturday.
For Example: To create a date stamp that outputs MM/DD/YY HH:MM, Enter S, as the Input
Type and enter the following Stamp Commands:
Stamp Commands
M//D//Y H:I
Field Requirements:
•
Stamp Commands are not required
• 0 to 31 characters allowed
Exhibit Text
This is a sequence of characters that is displayed on the screen only and does no user input. Enter
the text to be displayed. You will be prompted to enter Exhibit Text, only if the Input Type
is
E.
Field Requirements:
•
Exhibit Text is not required
• 0 to 31 characters allowed
• alpha, numeric, and all other ASCII characters are accepted
NOTE: Any ASCII control character may be input by a 3 character sequence of "/nn" (/nn is the
HEX value of the character). Since a / is the start of any HEX value, you must type "//"
to output a slash. Refer to Appendix K for Special Character values.
Screen Usage Parameters
The following four parameters specify the portion of the screen used by the current input
definition. These parameters must be defined when using a Data Input, Yes/No Input, or Exhibit
Text.
NOTE: The M3000 prevents the operator from specifying a starting position greater than the
ending position. If the prompt text is greater than or equal to the window defined, the
M3000 displays only part of the prompt and allows one space for the input window.