9Troubleshooting
9-5
Input Error Message while Using Lookup Tables
Message Solution
Input Not Found In
Lookup Table
Ensure input data matches one of the lookup table entries.
Lookup File Is Not In
Memory
Download the lookup file using, FUNCT + XMIT, Receive ASCII Files.
Input Not Found In
Lookup File
Enter or scan only valid data.
Input Not Found Accept
Anyway?
Enter or scan valid data, or answer 'Yes' to accept the data.
Troubleshooting Guide
Problem Definition Solution
PC Keyboard does not operate
after disconnecting the M3000
from the Keyboard Wedge Cable
Shunt is not connected to M3000
Y-Cable connector.
Connect M3000 shunt to Keyboard
Wedge Y-Cable connector, or
unplug Y-Cable and connect
keyboard connector directly to PC.
The 25-pin serial connector does
not fit my PC's 9-pin input.
Connector mismatch. Connect 25-pin to 9-pin adapter to
end of M3000 Serial or Serial
Y-Cable.
No data from M3000 Keypad. M3000 in non portable mode. Normal condition.
Difficulty scanning bar codes
while using Laser/CCD scanner.
Laser too close to bar code.
Scanner too far from bar code.
Scanner pointing angle incorrect.
Scan within the guidelines specified
for the scanner you are using.
Adjust Laser/CCD Opts/Timeout
M3000 does not accept special
character or function key codes.
Formatting error while
programming.
Precede HEX valure by a "/".
Use "//" to output a slash.
Short battery life. Continous operation in RS232
Serial or Serial Wedge modes on
battery power alone.
Use External Power Supply.
Automatic shut-off is disabled during
non portable modes.
Losing data during serial
communications.
Baud rate too fast.
Protocol incorrect.
Use slower baud rate.
Select appropriate protocol.
How do I select the proper
XMODEM mode?
No problem. M3000 auto detects proper
XMODEM mode, ie. Checksum,
CRC.
2 beeps at Power On and nothing
is displayed
LCD display error detected. Call for service.
M3000 locks up and will not shut
off.
NOTE: While in keyboard wedge
mode the M3000 cannot be shut
off.
M3000 Lock Up 1. Turn off computer.
2. Disconnect M3000 from the
computer.
3. Disconnect any external power
supply and remove the 9V
battery.
4. Reconnect 9V battery.
5. Press and hold down the N key
and R key. Then press the ON
key.
The M3000 will power up showing
the main display.