8-8
You can avoid this problem by using either of these options in each USER SUPPLIED input field:
1. Setting Input Size, Min=0
or
2. Require Input=N
Importing an ASCII Data File
The FUNCTION XMIT mode screens have been changed to accommodate the new features of
Version 2.0. Before attempting to use the XMIT mode, make sure the options selected under
FUNC SETUP, >Transmit Setup, match the setup parameters of the communications program
that you are using on the PC. Also, make sure that you have connected the M3000 RS232 serial
cable, or Modem cable. If you're using a modem we recommend you use XMODEM protocol. To
import the data file "DATA1", do the following:
1. Press the XMIT key. The display shows:
Transmit Select
>Upload Data
press the Down Arrow, followed by the ENTER key. The display shows:
Receive Select
>ASCII Files
2. Use the Up/Down arrow keys to select either RS232 Serial or Modem, and press the
ENTER key. The M3000 displays a "Receive Waiting" message or if you are using
XMODEM protocol, "Waiting for XMODEM Connect".
3. From your PC communications program select either Send File, or Upload and enter
the file name "DATA1". Press the ENTER key on the PC keyboard. Do not touch
the M3000 keyboard until after the M3000 displays:
Receive complete
Press the ENTER key.
The display shows:
Files Received
Data=1 LkUp=0
You can now exit the XMIT mode and use the data file from within the FUNCTION INPUT
mode. If the file transfer failed, the M3000 displays an appropriate error message. Correct your
communication settings and try again.